Vibration Of A Vertical Turbine Pump: MSI completed finite element vibration analysis of an automotive company’s proposed VTP installation. Analysis of the originally designed system indicated that there was a strong probability of resonant lateral vibration, in which the first “reed” frequency of the pump/motor/floor as a combined system would be driven by the 1200 RPM running speed. Whether or not the resonance would actually take place and how strongly it would affect the pump/motor system would depend in part on how firm the connection between the sub-floor beams and floor would be, where a particular pump would be located on the floor, and how stiffly the piping system would react at the discharge nozzle. In the analysis of the original system, however, under no set of assumptions was the margin between the predicted first reed natural frequency and the running speed equal to or greater than the Hydraulic Institute recommendation of 25 percent separation, or the common industry practice of minimum 15 percent separation.

Fortunately, no other potential natural frequency problems were evident, and in particular the second reed frequency, with a margin of about 25 percent above running speed, was shown to not shift down significantly if the first reed frequency resonance was de-tuned. This de-tuning was accomplished inexpensively by reducing pump base-to-foundation attachment stiffness. If the design had not been analyzed and modified, the pumps and motors would have been very balance-sensitive, and the initial installation’s vibration probably would have been in excess of the Hydraulic Institute standards. The excessive vibration may have led to chronic premature failure the motor bearings, discharge head stuffing box seal, and pump bowl bearings.

Adding a damper ring or a tuned vibration absorber to the motor top were also proposed as viable options, but were not done because of their extra complication. Adding dead mass to the motor top and/ or bowl assembly could have dropped the first reed frequency low enough to avoid the original problem, but it was shown by analysis that this would have also dropped the second reed frequency into the running speed range, trading one problem for another.

REAL-WORLD EXAMPLES AND CASE STUDIES

MSI In Action

Case Study

Improving Cost of Ownership with Vibration Risk Reduction: 1/2

Focusing on vibration and dynamics issues during the plant design phase of a project pays off with smoother commissioning and lower cost of ownership over the plant’s life.

Case Study

Simulating the Performance of a Spinal Implant

A manufacturer of an innovative spinal implant approached MSI for help in assessing the implant’s structural integrity.

Case Study

Dynamic Analysis of a Street Sweeper for the Manufacturer

Troubleshoot and identify potential opportunities for early bearing failure, MSI performed experimental modal analysis (EMA) and operational deflection shape (ODS) tests on a prototype unit for the manufacturer.