Turbine Publications
|
Order # |
|
425 MW Steam Turbine Commissioning -
MSI was called on behalf of an engineering construction firm building a new power plant in the Southern Hemisphere.
The plant was only weeks away from the commissioning deadline, after which hundreds of thousands of US$ per day liquidated damages would be due...
|
CS05-0124Rt |
|
A Cure for the Common Cold – in Turbines
...In a new power plant overseas, two newly installed aeroderivative gas turbine/ generator
sets were experiencing sudden and dramatic increases in vibration level over certain operating torque ranges...
|
CS00-0141Rt |
|
Aeroderivative Gas Turbine and Gearbox / Genset -
MSI was called on behalf of a customer who had seen a large increase in the vibration levels of
a particular LM500 Gas Turbine Generator Set being used to supply power to a large pharmaceutical facility ...
|
CS01-0115Rt |
|
Common Vibration Guidelines -
A listing of common vibration frequencies and their sources for rotating machinery on a nicely laminated desk side reference.
|
ML06-0134Rl Mailed upon Request |
|
Design Optimization of a Low Pressure Steam Turbine Stage -
Improve the performance of a low pressure (LP) steam turbine stage preserving original rotor count and hub design...
|
SB07-0127Rt |
|
Interference Diagrams:
When Campbell Diagrams Aren’t Enough -
...understand more about Interference Diagrams, how they are used...in assessing the potential for resonance problems in a centrifugal impeller or axial bladed disk...
|
T06-0137Rl Mailed upon Request
|
|
Multi-rotor Gas Turbine Rotordynamic Analysis Incorporating Casing Supports -
An area of concern for gas turbine OEM’s and end users is the effect of casing and structural supports on the rotordynamic response of multi-rotor systems...
|
CS05-0121Rt |
|
Power Steam Turbine Evaluation -
Vibration testing was performed on an African power plant steam turbine/ generator set to determine the reasons for excessive vibration...
|
SB00-0144Rt
Website only
|
|
Steam Turbine Driver Blade Erosion -
Following a lengthy period of service, the LP stages of a nuclear plant boiler feed pump
turbine were found to have suffered erosion damage...
|
SB00-0145Rt Website only |
|
Vibration Failures:
Dynamic Testing and Finite Element Modeling Have Been Successful Diagnostic Methods -
A well-practiced approach is needed to find solutions to failures due to vibration...
|
T08-0140RSl Mailed upon Request |