MSI endeavors to make most of our publications available in PDF format for you to download at your convenience. However, due to certain Copyright and distribution restrictions on some publications, we can not provide a PDF file for you to download and therefore request that you fill out the corresponding request form at the bottom of the publication page. We apologize for any inconvenience this may cause.

Static Structure Publications Order #
CO2 Absorber Column Vibration Problem Resolution - MSI investigates the source of high displacement vibration at the top of the absorber column at low frequency... CS06-0122S
Gear Tooth Failure Problem Resolution - MSI performs testing and analysis to determine root cause of gear tooth failures on an aeroderivative gas turbine power generation drivetrain... CS07-0139RSo
Impeller Vane Pass Acoustic Excitation of Pipe Resonance in a Nuclear Power Plant - MSI investigates and suggests practical solutions for premature failure of bearings and seals in a safety-related Decay Heat Removal Pump... CS06-0120RSo
Pump System Seismic Structural Analysis - MSI principals were contracted through a major OEM to perform their unique time averaged pulsing (TAP) impact modal testing on three 30 year old, reliable, packed-stuffing box, multistage barrel pumps in critical refinery process charging service...   CS00-0152RSp
Pump System Structural Analysis - MSI performs a seismic structural analysis on three identical large pump systems in a low-activity and high-activity nuclear waste treatment process... CS06-0129RSp
Resonant Acoustics Exciting Destructive Vibration at a Nuclear Power Plant - MSI determines the root cause and solution for the failure of 4 kV switchgear bearings in a nuclear power facility... CS06-0119RSo
Urea Screener Failure Problems - The screener had been suffering periodic failures due to cracks along the welds, plates, and structural beams … MSI .. to perform detailed vibration tests and FEA modal and stress analysis... CS00-0123S
Vertical Pump Lineshaft Failures - ...to determine the reasons for chronic lineshaft failures via field test and FEA in some 100 foot (30 meter) long vertical pumps driven by a diesel engine and a right angle gear, in service on an offshore oil platform. Modeling included the platform structural support system... CS98-0109RSp
Vibration Failures: Dynamic Testing and Finite Element Modeling Have Been Successful Diagnostic Methods - A well-practiced approach is needed to find solutions to failures due to vibration... T08-0140RSl
Mailed upon Request
 
Privacy Policy     Terms of Use     Trademarks


Mechanical Solutions, Inc.     11 Apollo Drive     Whippany, NJ  07981-1423
Phone: 973-326-9920     Fax: 973-326-9919     msi@mechsol.com

All content Copyright © 1996-2008 Mechanical Solutions, Inc.
Last modified: 05/10/08